GSA THREE PHASE PAD MOUNTED TRANSFORMER

Product Description:

Transformers are Conventional Three Phase Pad Type with the following

Base Model Design Specifications:

 

Product Design Compliance:

PROLEC GE DESIGNS, MANUFACTURES AND TEST TRANSFORMERS IN ACCORDANCE WITH THE LATEST APPLICABLE SECTIONS OF ANSI, NEMA AND IEEE STANDARDS.

 

PER ANSI C57.12.34, LOOP FEED, DEAD FRONT, MINIMUM DIMENSIONS.

COOPER HV BUSHINGS WELL 200 AMPS WITH REMOVABLE STUD 35 kV.

VG-100 DIELECTRIC FLUID.

TAPS 2 - 2.5% ABOVE AND BELOW.

BAYONET EXP FUSE + PARTIAL RANGE CLF WITH 3 COOPER BAY-O-NET FUSE ASSEMBLY WITH FLAPPER VALVE CAT# 4000361C99FV.

PER SPARE FUSES WE ARE QUOTING 3 SPARE EXP FUSES ONLY.

COOPER HV INSERTS 95 kV BIL - 200 AMPS (15 kV).

1 - 2 POSITION SWITCH.

STAINLESS STEEL 304L (TANK, BASE & SILL, CABINET).

MILD STEEL OPTION AVAILABLE (AT REDUCED PRICE).

VEGETABLE OIL VG-100 THAT IS SIMILAR TO FR3 (ENVIROTEMP).

 

all pad mounted transformers meets DFARS 252.211-7003, requirement Item Identification and Valuation.

75 KVA

DEALER PART NUMBER:   QRHX897-GSA

 

75 KVA, 3 PH, PAD, TRANSFORMER, 12000 DELTA – 208Y/120, PER ANSI C57.12.34, LOOP FEED, DEAD FRONT, COOPER HV BUSHINGS, VG-100 DIELECTRIC FLUID, TAPS 2 - 2.5% ABOVE AND BELOW, BAYONET EXP FUSE + PARTIAL RANGE CLF WITH 3 COOPER BAY-O-NET FUSE ASSY WITH FLAPPER VALVE, VEGETABLE OIL VG-100, STAINLESS STEEL 304L (TANK, BASE & SILL, CABINET), MILD STEEL OPTION AVAILABLE (AT REDUCED PRICE). PLEASE SEE OUR TERMS & CONDITIONS FOR ADDITIONAL SPECIFICATIONS.

DEALER PART NUMBER:   QRHX898-GSA

                 

75KVA 3PH PAD TRANSFORMER 12000 DELTA – 480/240 TAP

 

75 KVA, 3 PH, PAD, TRANSFORMER, 12000 DELTA – 480/240 TAP, PER ANSI C57.12.34, LOOP FEED, DEAD FRONT, COOPER HV BUSHINGS, VG-100 DIELECTRIC FLUID, TAPS 2 - 2.5% ABOVE AND BELOW, BAYONET EXP FUSE + PARTIAL RANGE CLF WITH 3 COOPER BAY-O-NET FUSE ASSY WITH FLAPPER VALVE, VEGETABLE OIL VG-100, STAINLESS STEEL 304L (TANK, BASE & SILL, CABINET), MILD STEEL OPTION AVAILABLE (AT REDUCED PRICE). PLEASE SEE OUR TERMS & CONDITIONS FOR ADDITIONAL SPECIFICATIONS.

DEALER PART NUMBER:   QRHX901-GSA

                  

75KVA 3PH PAD TRANSFORMER 12000 DELTA – 480Y/277

 

75 KVA, 3 PH, PAD, TRANSFORMER, 12000 DELTA – 480Y/277, PER ANSI C57.12.34, LOOP FEED, DEAD FRONT, COOPER HV BUSHINGS, VG-100 DIELECTRIC FLUID, TAPS 2 - 2.5% ABOVE AND BELOW, BAYONET EXP FUSE + PARTIAL RANGE CLF WITH 3 COOPER BAY-O-NET FUSE ASSY WITH FLAPPER VALVE, VEGETABLE OIL VG-100, STAINLESS STEEL 304L (TANK, BASE & SILL, CABINET), MILD STEEL OPTION AVAILABLE (AT REDUCED PRICE). PLEASE SEE OUR TERMS & CONDITIONS FOR ADDITIONAL SPECIFICATIONS.

DEALER PART NUMBER:   QRHX903-GSA

                 

75KVA 3PH PAD TRANSFORMER 12470 DELTA – 480Y/277

 

75 KVA, 3 PH, PAD, TRANSFORMER, 12470 DELTA – 480Y/277, PER ANSI C57.12.34, LOOP FEED, DEAD FRONT, COOPER HV BUSHINGS, VG-100 DIELECTRIC FLUID, TAPS 2 - 2.5% ABOVE AND BELOW, BAYONET EXP FUSE + PARTIAL RANGE CLF WITH 3 COOPER BAY-O-NET FUSE ASSY WITH FLAPPER VALVE, VEGETABLE OIL VG-100, STAINLESS STEEL 304L (TANK, BASE & SILL, CABINET), MILD STEEL OPTION AVAILABLE (AT REDUCED PRICE). PLEASE SEE OUR TERMS & CONDITIONS FOR ADDITIONAL SPECIFICATIONS.

Can't find what you're looking for? Please contact one of our customer service representatives.

For any inquiries, questions or quote requests

please call: 1-888-646-2668

INCON Inc.

"A Unique Service Team"